| | Output Voltage Minimum Load Start Up Delay Start Up Rise TimeHold Up Time Over/Undershoot Transient ResponseOver Voltage Protection Over Current ProtectionOver Temperature ProtectionShort Circuit Protection Temperature Coefficient Remote On/OffCurrent Share
| | See table See table < 500 mSec maximum < 50mSec to 1Sec measured from10% to 90% > 20 mS/110V < 10% max at tum on/of < 4% max piation, recovery to within 1% in 1 mSec for 25% load change +3.3V:3.9V ~ 4.5V +5V:5.7V ~ 6.5V +12V:13.3V ~ 14.5V +3.3V:41.8A ~ 53.2A +5V:41.8A ~ 53.2A +12V1-2:18.5A ~ 21.5A +12V3-4:23.0A ~ 26.0A Primary & secondary protection with auto recovery No damage, resistance ≦0.01Ω ≦0.05%/°C after 30 min operating On = PSON ≦0.8V, low Off = PSON ≧2.4V, high, open 2 supplies to share within ±10%
|
| | |
| | | | Operating Temperature Cooling Operating Humidity Storage Temperature Operating Altitude Shock Operating Non-Operating Vibration Operating Non-Operating | | 0 to 40°C 9 CFM airflow required 5 - 90%, Non-condensing -40°C to +70°C sea level to 6,500 feet 5G, 11 mSec, half sine 3 axes 30G, 11 mSec, half sine 3 axes 0.5G, 10 Hz to 500 Hz, 3axes 2G, 10 Hz to 300 Hz, 3axes |
| | |
| | EmissionsHarmonic Currents Voltage Flicker EFT/Burst Surge Conducted Immunity Safety Approvals | | En55022, class B Conducted En55022, class B Radiated EN61000-3-2, Class D EN61000-3-3 EN61000-4-4, level 3 Perf Criteria B EN61000-4-5, level 3 Perf Criteria B EN61000-4-6, 10Vrms Perf Criteria A UL/cUL60950-1, TUV, CB, CE, CCC, FCC, NEMKO Report
|
| | |
|